| Ex protection |
Flameproof Exd |
| Protection code |
EX II 2 G EEx de IIC T6
|
| ATEX certificate |
PTB 03 ATEX 1097 X
|
| Rated values: |
|
| AC voltage: |
250V
|
| AC Current: |
10A |
| Frequency: |
50/60 Hz
|
| DC voltage: |
60V |
| DC current: |
2,5A |
| Fuse capacity: |
10A - without thermal protection
20A gl - with thermal protection
|
| Transmission rate: |
up to 100 MBit/s, (acc. to TIA/EIA-568-B.2 Category 5e)
|
| Frequency range: |
0 MHz ... 100 MHz (Fast Ethernet compatible)
|
|
|
| Cable entry: |
8591/...-..-...1 4 mm ... 7.5 mm
8591/...-..-...2 7.5 mm ... 11 mm
|
| Live Demate: |
Yes |
| Igress protection |
IP 66 / IP 68 (2 m water column, 1 hour)
(with protective caps closed and secured as well as properly fitted and secured components)
|
| Ambient temp.: |
- 55 °C ... + 40 °C (with rated current 10 A)
- 55 °C ... + 75 °C (with rated current 2 A)
|
| Material |
brass, nickel-plated; plastic, polyamide resin; stainless steel AISI 316L
|